<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-17 07-38-28
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 40 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 2.9 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
5 kHz 60 kHz 18900 0,0529
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,3 dBr -0,01 dBr 0,5 dBr 9,6
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 7:38, 17.09.2026
RT
"Analyzy a komentare - deni z domova i ze sveta "
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 60 kHz MIN: 5 kHz % above 77 kHz: 0,0529 Acquired: 2026/09/17 7:38:21 Total samples: 18900 Equivalent time: 0:15:45 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 0,5 dBr MIN: -0,3 dBr AVE: -0,01 dBr % above 0,2 dBr: 9,6 Last value: 0,0 dBr (2026/09/17 7:38:20) 07:24 07:26 07:28 07:30 07:32 07:34 07:36 07:38 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality